Fit dose-response relationships to dose-response data and calculate biometric results for (eco)toxicity evaluation using the drc package

drcfit(data, chooseone = TRUE, probit = TRUE, logit = FALSE,
  weibull = FALSE, linlogit = FALSE, level = 0.95,
  showED50 = FALSE, EDx = NULL)

Arguments

data

A data frame containing dose-response data. The data frame has to contain at least a factor called “substance”, a numeric vector “dose” with the dose values, a vector called “unit” containing the unit used for the dose and a numeric vector “response” with the response values of the test system normalized between 0 and 1. Such a data frame can be easily obtained if a compliant RODBC data source is available for use in conjunction with the function drdata.

If there is a column called “ok” and it is set to “no fit” in a specific line, then the corresponding data point will be excluded from the fitting procedure, although it will be plotted.

probit

A boolean defining if cumulative density curves of normal distributions are fitted against the decadic logarithm of the dose. Default ist TRUE. Note that the parameter definitions used in the model are different to the ones used in drfit. Parameter e from LN.2 is listed as a here, and parameter b from there is listed as b.

logit

A boolean defining if cumulative density curves of logistic distributions plogis are fitted to the decadic logarithm of the dose. Default is FALSE. Again the parameter definitions used in the model are different to the ones used in drfit. Parameter e from LL.2 is listed as a here, and parameter b from LL.2 is listed as b.

weibull

A boolean defining if Weibull dose-response models (W1.2 are fitted to the untransformed dose. Default is FALSE. Note that the results differ from the ones obtained with drfit, due to a different model specification.

linlogit

A boolean defining if the linear-logistic function linlogitf as defined by van Ewijk and Hoekstra 1993 is fitted to the data. Default is FALSE. Obtaining the ED50 (and EDx values in general) uses ED internally and does not always give a result.

level

The level for the confidence interval listed for the log ED50.

chooseone

If TRUE (default), the models are tried in the order linlogit, probit, logit, weibull, and the first model that produces a valid fit is used. If FALSE, all models that are set to TRUE and that can be fitted will be reported.

EDx

A vector of inhibition values x in percent for which the corresponding doses EDx should be reported.

showED50

If set to TRUE, the ED50 and its confidence interval on the original dose scale (not log scale) is included in the output.

Value

A dataframe with the attribute models holding a list of the fitted dose-response models of class nls. The dataframe has at least one line for each substance.

The following variables are in the dataframe:

Substance

The name of the substance

ndl

The number of dose levels in the raw data

n

The total number of data points in the raw data used for the fit

lld

The decadic logarithm of the lowest dose

lhd

The total number of data points in the raw data used for the fit

mtype

If the data did not show a mean response < 0.5 at the highest dose level, the modeltype is set to “inactive”. If the mean response at the lowest dose is smaller than 0.5, the modeltype is set to “active”. In both cases, no fitting procedure is carried out. If the fitted ED50 is higher than the highest dose, “no fit” is given here.

logED50

The decadic logarithm of the ED50

low %

The lower bound of the confidence interval of log ED50. The name of the column depends on the requested confidence level.

high %

The higher bound of the confidence interval of log ED50. The name of the column depends on the requested confidence level.

unit

The unit used for the dose levels in the dose-response data

sigma

The square root of the estimated variance of the random error as returned by summary.drc.

a

For the linlogit model, this is the parameter e from BC.4. For the probit and the logit model, this is the ED50. For the weibull model, this is parameter e from W1.2. Note that the Weibull model is fitted to the untransformed data.

b

For the linlogit, probit, logit and weibull models, these are the parameters b from BC.4, LN.2, LL.2 and W1.2, respectively. Note that the parameter definitions (and in the case of Weibull, the model used) are different to the ones used in drfit.

c

Only the “linlogit” fit produces a third parameter c, which is the parameter f from the BC.4 function.

If the parameter showED50 was set to TRUE, the ED50 values and their confidence intervals are also included on the original dose scale. If one or more response leves were specified in the argument EDx, the corresponding dose levels are given in addition, together with their confidence intervals as calculated by ED from the drc package.

Note

There is a demo for each dataset that can be accessed by demo(dataset)

See also

Further examples are given in help pages to the datasets antifoul, IM1xIPC81 and IM1xVibrio.

Examples

data(antifoul) r <- drcfit(antifoul, showED50 = TRUE, EDx = c(5, 10, 20))
#> #> TBT: Fitting data...
#> #> Zn Pyrithion: Fitting data...
format(r, digits = 2)
#> Substance ndl n lld lhd mtype logED50 2.5% 97.5% unit sigma a #> 1 TBT 38 135 -2.7 2.4 probit -0.16 -0.28 -0.072 microM 0.19 0.68 #> 2 Zn Pyrithion 27 81 -2.1 2.0 probit -0.40 -0.52 -0.303 microM 0.23 0.40 #> b ED50 ED50 2.5% ED50 97.5% EDx5 EDx5 2.5% EDx5 97.5% EDx10 EDx10 2.5% #> 1 -0.64 0.68 0.52 0.85 0.053 0.015 0.091 0.093 0.040 #> 2 -1.04 0.40 0.30 0.50 0.082 0.023 0.142 0.117 0.048 #> EDx10 97.5% EDx20 EDx20 2.5% EDx20 97.5% #> 1 0.15 0.18 0.11 0.26 #> 2 0.19 0.18 0.10 0.26