Runoff loss percentages as used in Exposit 3
Source:R/PEC_sw_exposit_runoff.R
perc_runoff_exposit.Rd
A table of the loss percentages used in Exposit 3 for the twelve different Koc classes
Format
A data frame with percentage values for the dissolved fraction and the fraction bound to eroding particles, with Koc classes used as row names
- Koc_lower_bound
The lower bound of the Koc class
- dissolved
The percentage of the applied substance transferred to an adjacent water body in the dissolved phase
- bound
The percentage of the applied substance transferred to an adjacent water body bound to eroding particles
Source
Excel 3.02 spreadsheet available from https://www.bvl.bund.de/SharedDocs/Downloads/04_Pflanzenschutzmittel/zul_umwelt_exposit.html
Examples
print(perc_runoff_exposit)
#> Koc_lower_bound dissolved bound
#> 0-20 0 0.110 0.000
#> >20-50 20 0.151 0.000
#> >50-100 50 0.197 0.000
#> >100-200 100 0.248 0.001
#> >200-500 200 0.224 0.004
#> >500-1000 500 0.184 0.020
#> >1000-2000 1000 0.133 0.042
#> >2000-5000 2000 0.084 0.091
#> >5000-10000 5000 0.037 0.159
#> >10000-20000 10000 0.031 0.192
#> >20000-50000 20000 0.014 0.291
#> >50000 50000 0.001 0.451