# Runoff loss percentages as used in Exposit 3 A table of the loss percentages used in Exposit 3 for the twelve different Koc classes ## Usage ``` r perc_runoff_exposit ``` ## Format A data frame with percentage values for the dissolved fraction and the fraction bound to eroding particles, with Koc classes used as row names - Koc_lower_bound: The lower bound of the Koc class - dissolved: The percentage of the applied substance transferred to an adjacent water body in the dissolved phase - bound: The percentage of the applied substance transferred to an adjacent water body bound to eroding particles ## Source Excel 3.02 spreadsheet available from ## Examples ``` r print(perc_runoff_exposit) #> Koc_lower_bound dissolved bound #> 0-20 0 [L/kg] 0.110 0.000 #> >20-50 20 [L/kg] 0.151 0.000 #> >50-100 50 [L/kg] 0.197 0.000 #> >100-200 100 [L/kg] 0.248 0.001 #> >200-500 200 [L/kg] 0.224 0.004 #> >500-1000 500 [L/kg] 0.184 0.020 #> >1000-2000 1000 [L/kg] 0.133 0.042 #> >2000-5000 2000 [L/kg] 0.084 0.091 #> >5000-10000 5000 [L/kg] 0.037 0.159 #> >10000-20000 10000 [L/kg] 0.031 0.192 #> >20000-50000 20000 [L/kg] 0.014 0.291 #> >50000 50000 [L/kg] 0.001 0.451 ```