Calculate initial predicted environmental concentrations in surface water due to drainage using the UK method

Usage

PEC_sw_drainage_UK_ini(rate, interception = 0, Koc, latest_application = NULL, soil_DT50 = NULL, model = NULL, model_parms = NULL)

Arguments

rate
Application rate in g/ha
interception
The fraction of the application rate that does not reach the soil
Koc
The sorption coefficient normalised to organic carbon in L/kg
latest_application
Latest application date, formatted as e.g. "01 July"
soil_DT50
Soil degradation half-life, if SFO kinetics are to be used
model
The degradation model to be used. Either one of "FOMC", "DFOP", "HS", or "IORE", or an mkinmod object
model_parms
A named numeric vector containing the model parameters

Value

The predicted concentration in surface water in µg/L

Description

This implements the method specified in the UK data requirements handbook and was checked against the spreadsheet published on the CRC website

Examples

PEC_sw_drainage_UK_ini(150, Koc = 100)
[1] 8.076923

Author

Johannes Ranke