Calculate initial predicted environmental concentrations in surface water due to drift

Usage

PEC_sw_drift_ini(rate, applications = 1, water_depth = 30, drift_data = "JKI", crop = "Ackerbau", distances = c(1, 5, 10, 20), rate_units = "g/ha", PEC_units = "µg/L")

Arguments

rate
Application rate in units specified below
applications
Number of applications for selection of drift percentile
water_depth
Depth of the water body in cm
drift_data
Source of drift percentage data
crop
Crop name (use German names for JKI data), defaults to "Ackerbau"
distances
The distances in m for which to get PEC values
rate_units
Defaults to g/ha
PEC_units
Requested units for the calculated PEC. Only µg/L currently supported

Value

The predicted concentration in surface water

Description

This is a basic, vectorised form of a simple calculation of a contaminant concentration in surface water based on complete, instantaneous mixing with input via spray drift.

Examples

PEC_sw_drift_ini(100)
1 m 5 m 10 m 20 m 0.92333333 0.19000000 0.09666667 0.05000000

Author

Johannes Ranke