diff options
author | Johannes Ranke <johannes.ranke@jrwb.de> | 2025-01-22 17:14:04 +0100 |
---|---|---|
committer | Johannes Ranke <johannes.ranke@jrwb.de> | 2025-01-22 17:14:04 +0100 |
commit | c7b841c93dc2f3228dfe65ebd3bdd7a7f546fb96 (patch) | |
tree | 80e188b68b1fafd1ed100ee121397938fb8d2a91 /man | |
parent | cfcd58348dc8cbf7010231bfe902867bb30a8b3f (diff) |
Satisfy R CMD check
- Depend on R >= 3.5.0, because the format used for the data is not
known to earlier R versions
- Rename the datasets from `test` to their proper name
Diffstat (limited to 'man')
-rw-r--r-- | man/din32645.Rd | 3 | ||||
-rw-r--r-- | man/din38402b1.Rd | 3 | ||||
-rw-r--r-- | man/din38402b3.Rd | 3 | ||||
-rw-r--r-- | man/din38402b6.Rd | 3 | ||||
-rw-r--r-- | man/din38402c3.Rd | 3 | ||||
-rw-r--r-- | man/linearity.Rd | 10 | ||||
-rw-r--r-- | man/massart97ex1.Rd | 3 | ||||
-rw-r--r-- | man/massart97ex3.Rd | 3 | ||||
-rw-r--r-- | man/rl95_cadmium.Rd | 3 | ||||
-rw-r--r-- | man/rl95_toluene.Rd | 3 | ||||
-rw-r--r-- | man/utstats14.Rd | 3 |
11 files changed, 36 insertions, 4 deletions
diff --git a/man/din32645.Rd b/man/din32645.Rd index a8e6a31..5b9603f 100644 --- a/man/din32645.Rd +++ b/man/din32645.Rd @@ -7,6 +7,9 @@ \format{ A dataframe containing 10 rows of x and y values. } +\usage{ +din32645 +} \description{ Sample dataset to test the package. } diff --git a/man/din38402b1.Rd b/man/din38402b1.Rd index 10ccddc..2c538b8 100644 --- a/man/din38402b1.Rd +++ b/man/din38402b1.Rd @@ -8,6 +8,9 @@ A tibble containing 12 concentration levels with the respective instrument response values. } +\usage{ +din38402b1 +} \description{ Example dataset B.1 from DIN 38402 with concentrations in µg/L and the extinction as response measured using continuous flow analysis (CFA) according to diff --git a/man/din38402b3.Rd b/man/din38402b3.Rd index b4b5504..83abd0f 100644 --- a/man/din38402b3.Rd +++ b/man/din38402b3.Rd @@ -8,6 +8,9 @@ A tibble containing 13 concentration levels and the respective instrument response values. } +\usage{ +din38402b3 +} \description{ Example dataset B.3 from DIN 38402. Cu was measured according to ISO 11885, using ICP-OES. The concentration are reported in mg/L and the response as diff --git a/man/din38402b6.Rd b/man/din38402b6.Rd index feb3577..289ee41 100644 --- a/man/din38402b6.Rd +++ b/man/din38402b6.Rd @@ -8,6 +8,9 @@ A tibble containing 12 concentration levels and the respective instrument response values. } +\usage{ +din38402b6 +} \description{ Example dataset B.6 from DIN 38402 measured using LC-MS/MS. The concentrations are reported in in µg/L and the response in arbitrary diff --git a/man/din38402c3.Rd b/man/din38402c3.Rd index 7c00999..e9ac83e 100644 --- a/man/din38402c3.Rd +++ b/man/din38402c3.Rd @@ -8,6 +8,9 @@ A tibble containing 10 concentration levels and the respective response values. } +\usage{ +din38402c3 +} \description{ Example dataset C.3 from DIN 38402 determined by ion chromatography. Concentrations are reported in mg/L and the extinction as response. diff --git a/man/linearity.Rd b/man/linearity.Rd index aa3d857..52c2423 100644 --- a/man/linearity.Rd +++ b/man/linearity.Rd @@ -41,12 +41,14 @@ identification of non-linear behaviour of calibration curves (Andrade and Gomes-Carracedo, 2013). } \examples{ -data(din32645) +# Continuous Flow Analysis (CFA) data +data(din38402b1) + # Point-to-point slope plot -linearity(din32645$x, din32645$y, method = "slope") +linearity(din38402b1$conc, din38402b1$ext, method = "slope") # Curvature plot -linearity(din32645$x, din32645$y, method = "curvature", tolerance = 0.2) +linearity(din38402b1$conc, din38402b1$ext, method = "curvature") } \references{ @@ -58,5 +60,5 @@ Mandel's test to check for nonlinearity in laboratory calibrations. Analytical Methods 5(5), 1145 - 1149. } \author{ -Anil Axel Tellbüscher +Anıl Axel Tellbüscher } diff --git a/man/massart97ex1.Rd b/man/massart97ex1.Rd index d154a9c..c49f416 100644 --- a/man/massart97ex1.Rd +++ b/man/massart97ex1.Rd @@ -12,6 +12,9 @@ Massart, L.M, Vandenginste, B.G.M., Buydens, L.M.C., De Jong, S., Lewi, P.J., Smeyers-Verbeke, J. (1997) Handbook of Chemometrics and Qualimetrics: Part A, Chapter 8. } +\usage{ +massart97ex1 +} \description{ Sample dataset from p. 175 to test the package. } diff --git a/man/massart97ex3.Rd b/man/massart97ex3.Rd index 284a435..82d3191 100644 --- a/man/massart97ex3.Rd +++ b/man/massart97ex3.Rd @@ -13,6 +13,9 @@ Massart, L.M, Vandenginste, B.G.M., Buydens, L.M.C., De Jong, S., Lewi, P.J., Smeyers-Verbeke, J. (1997) Handbook of Chemometrics and Qualimetrics: Part A, Chapter 8. } +\usage{ +massart97ex3 +} \description{ Sample dataset from p. 188 to test the package. } diff --git a/man/rl95_cadmium.Rd b/man/rl95_cadmium.Rd index 8e0b02c..db6a841 100644 --- a/man/rl95_cadmium.Rd +++ b/man/rl95_cadmium.Rd @@ -13,6 +13,9 @@ six calibration standards. Rocke, David M. und Lorenzato, Stefan (1995) A two-component model for measurement error in analytical chemistry. Technometrics 37(2), 176-184. } +\usage{ +rl95_cadmium +} \description{ Dataset reproduced from Table 1 in Rocke and Lorenzato (1995). } diff --git a/man/rl95_toluene.Rd b/man/rl95_toluene.Rd index 1f8836a..2e0f3a5 100644 --- a/man/rl95_toluene.Rd +++ b/man/rl95_toluene.Rd @@ -12,6 +12,9 @@ six calibration standards. Rocke, David M. und Lorenzato, Stefan (1995) A two-component model for measurement error in analytical chemistry. Technometrics 37(2), 176-184. } +\usage{ +rl95_toluene +} \description{ Dataset reproduced from Table 4 in Rocke and Lorenzato (1995). The toluene amount in the calibration samples is given in picograms per 100 µL. diff --git a/man/utstats14.Rd b/man/utstats14.Rd index 1b739d4..bb952ff 100644 --- a/man/utstats14.Rd +++ b/man/utstats14.Rd @@ -14,6 +14,9 @@ Tutorial website maintained by the Departments of Chemistry, University of Toronto. \url{https://sites.chem.utoronto.ca/chemistry/coursenotes/analsci/stats/index.html} } +\usage{ +utstats14 +} \description{ Dataset read into R from \url{https://sites.chem.utoronto.ca/chemistry/coursenotes/analsci/stats/files/example14.xls}. |