aboutsummaryrefslogblamecommitdiff
path: root/pkg/man/PEC_sw_drift_NL.Rd
blob: 404123afcbd29d23d0ee95f5418a6bd44c88ca1a (plain) (tree)




































                                                                                        
% Generated by roxygen2: do not edit by hand
% Please edit documentation in R/PEC_sw_drift_NL.R
\name{PEC_sw_drift_NL}
\alias{PEC_sw_drift_NL}
\title{Calculate predicted environmental concentrations in surface water due to drift}
\usage{
PEC_sw_drift_NL(rate, applications = 1, water_depth = 30,
  drift_percentages = c(1), rate_units = "g/ha", PEC_units = "µg/L")
}
\arguments{
\item{rate}{Application rate in units specified below}

\item{applications}{Number of applications for selection of drift percentile}

\item{water_depth}{Depth of the water body in cm}

\item{drift_percentages}{Percentage drift values for which to calculate PECsw}

\item{rate_units}{Defaults to g/ha}

\item{PEC_units}{Requested units for the calculated PEC. Only µg/L currently supported}
}
\value{
The predicted concentration in surface water
}
\description{
This is a basic, vectorised form of a simple calculation of a contaminant
concentration in surface water based on complete, instantaneous mixing
with input via spray drift.
}
\examples{
PEC_sw_drift_NL(100)
}
\author{
Johannes Ranke
}