diff options
author | Johannes Ranke <jranke@uni-bremen.de> | 2024-08-26 17:11:43 +0200 |
---|---|---|
committer | Johannes Ranke <jranke@uni-bremen.de> | 2024-08-26 17:11:43 +0200 |
commit | 913c383880da2a5f4bdb71c8a82107afbad6ef13 (patch) | |
tree | 1c5a988748fc49fde4c279a96650deb26039b711 /man | |
parent | 9e62ed638e530a5cebebf491de055caca49a56ef (diff) | |
parent | 396ba6c42252426a132be56b9f417786a1f276e3 (diff) |
Merge branch 'main' into crop_group
Diffstat (limited to 'man')
-rw-r--r-- | man/PEC_sw_drift.Rd | 14 | ||||
-rw-r--r-- | man/PEC_sw_exposit_drainage.Rd | 2 | ||||
-rw-r--r-- | man/PEC_sw_exposit_runoff.Rd | 14 | ||||
-rw-r--r-- | man/PEC_sw_sed.Rd | 10 | ||||
-rw-r--r-- | man/perc_runoff_exposit.Rd | 2 | ||||
-rw-r--r-- | man/perc_runoff_reduction_exposit.Rd | 2 |
6 files changed, 28 insertions, 16 deletions
diff --git a/man/PEC_sw_drift.Rd b/man/PEC_sw_drift.Rd index a24b783..771687e 100644 --- a/man/PEC_sw_drift.Rd +++ b/man/PEC_sw_drift.Rd @@ -7,7 +7,7 @@ PEC_sw_drift( rate, applications = 1, - water_depth = 30, + water_depth = as_units("30 cm"), drift_percentages = NULL, drift_data = c("JKI", "RF"), crop_group_JKI = c("Ackerbau", "Obstbau frueh", "Obstbau spaet", "Weinbau frueh", @@ -16,14 +16,15 @@ PEC_sw_drift( "fruit, early", "aerial"), distances = c(1, 5, 10, 20), formula = c("Rautmann", "FOCUS"), - water_width = 100, + water_width = as_units("100 cm"), side_angle = 90, rate_units = "g/ha", PEC_units = "µg/L" ) } \arguments{ -\item{rate}{Application rate in units specified below} +\item{rate}{Application rate in units specified below, or with units defined via the +\code{units} package.} \item{applications}{Number of applications for selection of drift percentile} @@ -53,7 +54,8 @@ calculated as described in Chapter 5.4.5 of the FOCUS surface water guidance} \item{side_angle}{The angle of the side of the water relative to the bottom which is assumed to be horizontal, in degrees. The SYNOPS model assumes 45 degrees here.} -\item{rate_units}{Defaults to g/ha} +\item{rate_units}{Defaults to g/ha. For backwards compatibility, only used +if the specified rate does not have \link[units:units]{units::units}].} \item{PEC_units}{Requested units for the calculated PEC. Only µg/L currently supported} } @@ -65,6 +67,10 @@ This is a basic, vectorised form of a simple calculation of a contaminant concentration in surface water based on complete, instantaneous mixing with input via spray drift. } +\details{ +It is recommened to specify the arguments \code{rate}, \code{water_depth} and +\code{water_width} using \link[units:units]{units::units} from the \code{units} package. +} \examples{ PEC_sw_drift(100) # Alternatively, we can use the formula for a single application to diff --git a/man/PEC_sw_exposit_drainage.Rd b/man/PEC_sw_exposit_drainage.Rd index b145d5c..2917f8a 100644 --- a/man/PEC_sw_exposit_drainage.Rd +++ b/man/PEC_sw_exposit_drainage.Rd @@ -1,5 +1,5 @@ % Generated by roxygen2: do not edit by hand -% Please edit documentation in R/PEC_sw_exposit_runoff.R +% Please edit documentation in R/PEC_sw_exposit.R \name{PEC_sw_exposit_drainage} \alias{PEC_sw_exposit_drainage} \title{Calculate PEC surface water due to drainage as in Exposit 3} diff --git a/man/PEC_sw_exposit_runoff.Rd b/man/PEC_sw_exposit_runoff.Rd index fca5553..393ed29 100644 --- a/man/PEC_sw_exposit_runoff.Rd +++ b/man/PEC_sw_exposit_runoff.Rd @@ -1,5 +1,5 @@ % Generated by roxygen2: do not edit by hand -% Please edit documentation in R/PEC_sw_exposit_runoff.R +% Please edit documentation in R/PEC_sw_exposit.R \name{PEC_sw_exposit_runoff} \alias{PEC_sw_exposit_runoff} \title{Calculate PEC surface water due to runoff and erosion as in Exposit 3} @@ -12,11 +12,11 @@ PEC_sw_exposit_runoff( rate, interception = 0, Koc, - DT50 = Inf, - t_runoff = 3, + DT50 = set_units(Inf, "d"), + t_runoff = set_units(3, "days"), exposit_reduction_version = c("3.02", "3.01a", "3.01a2", "2.0"), - V_ditch = 30, - V_event = 100, + V_ditch = set_units(30, "m3"), + V_event = set_units(100, "m3"), dilution = 2 ) } @@ -56,6 +56,10 @@ for the different distances. If the rate was given in g/ha, the PECsw are in mic This is a reimplementation of the calculation described in the Exposit 3.02 spreadsheet file, in the worksheet "Konzept Runoff". } +\details{ +It is recommened to specify the arguments \code{rate}, \code{Koc}, \code{DT50}, \code{t_runoff}, \code{V_ditch} and \code{V_event} +using \link[units:units]{units::units} from the \code{units} package. +} \examples{ PEC_sw_exposit_runoff(500, Koc = 150) PEC_sw_exposit_runoff(600, Koc = 10000, DT50 = 195, exposit = "3.01a") diff --git a/man/PEC_sw_sed.Rd b/man/PEC_sw_sed.Rd index bc82ee3..0ebfd28 100644 --- a/man/PEC_sw_sed.Rd +++ b/man/PEC_sw_sed.Rd @@ -9,9 +9,9 @@ PEC_sw_sed( PEC_sw, percentage = 100, method = "percentage", - sediment_depth = 5, - water_depth = 30, - sediment_density = 1.3, + sediment_depth = set_units(5, "cm"), + water_depth = set_units(30, "cm"), + sediment_density = set_units(1.3, "kg/L"), PEC_sed_units = c("µg/kg", "mg/kg") ) } @@ -27,7 +27,7 @@ which the corresponding sediment concentration is to be estimated} \item{water_depth}{Depth of the water body in cm} -\item{sediment_density}{The density of the sediment in L/kg (equivalent to +\item{sediment_density}{The density of the sediment in kg/L (equivalent to g/cm3)} \item{PEC_sed_units}{The units of the estimated sediment PEC value} @@ -40,6 +40,8 @@ The method 'percentage' is equivalent to what is used in the CRD spreadsheet PEC calculator } \examples{ +library(pfm) +library(units) PEC_sw_sed(PEC_sw_drift(100, distances = 1), percentage = 50) } \author{ diff --git a/man/perc_runoff_exposit.Rd b/man/perc_runoff_exposit.Rd index 47ea586..e30ab73 100644 --- a/man/perc_runoff_exposit.Rd +++ b/man/perc_runoff_exposit.Rd @@ -1,5 +1,5 @@ % Generated by roxygen2: do not edit by hand -% Please edit documentation in R/PEC_sw_exposit_runoff.R +% Please edit documentation in R/PEC_sw_exposit.R \docType{data} \name{perc_runoff_exposit} \alias{perc_runoff_exposit} diff --git a/man/perc_runoff_reduction_exposit.Rd b/man/perc_runoff_reduction_exposit.Rd index 2fc32a6..4514a58 100644 --- a/man/perc_runoff_reduction_exposit.Rd +++ b/man/perc_runoff_reduction_exposit.Rd @@ -1,5 +1,5 @@ % Generated by roxygen2: do not edit by hand -% Please edit documentation in R/PEC_sw_exposit_runoff.R +% Please edit documentation in R/PEC_sw_exposit.R \docType{data} \name{perc_runoff_reduction_exposit} \alias{perc_runoff_reduction_exposit} |