+library(pfm)
+context("UK drainage PEC calculations")
+
+test_that("The mobility classification and the drained percentage are correct", {
+ # Expected results are from the CRD drainage calculator, retrieved 2015-06-11
+
+ expect_equivalent(SSLRC_mobility_classification(1), list("Very mobile", 1.9))
+ expect_equivalent(SSLRC_mobility_classification(15), list("Mobile", 1.9))
+ expect_equivalent(SSLRC_mobility_classification(30), list("Mobile", 1.9))
+ expect_equivalent(SSLRC_mobility_classification(74.9), list("Mobile", 1.9))
+ expect_equivalent(SSLRC_mobility_classification(75), list("Moderately mobile", 0.7))
+ expect_equivalent(SSLRC_mobility_classification(100), list("Moderately mobile", 0.7))
+ expect_equivalent(SSLRC_mobility_classification(800), list("Slightly mobile", 0.5))
+ expect_equivalent(SSLRC_mobility_classification(2000), list("Slightly mobile", 0.02))
+ expect_equivalent(SSLRC_mobility_classification(5000), list("Non mobile", 0.01))
+})
+
+test_that("UK drainflow PECs are correct", {
+ # Expected results are from the CRD drainage calculator, retrieved 2015-06-11, except
+ # for the third example from the data requirements handbook
+
+ # This is the first example calculation from the data requirements handbook, where they give
+ # 8.07 µg/L as the result (obviously a rounding error).
+ expect_equal(round(PEC_sw_drainage_UK(150, interception = 0, Koc = 100), 4), 8.0769)
+
+ # This is the second example calculation from the data requirements handbook
+ expect_equal(round(PEC_sw_drainage_UK(90, interception = 0, Koc = 10), 4), 13.1538)
+
+ # This is the third example calculation from the data requirements handbook,
+ expect_equal(round(PEC_sw_drainage_UK(60, interception = 0.5, Koc = 550,
+ latest_application = "01 July",
+ soil_DT50 = 200), 2), 0.84)
+})