aboutsummaryrefslogtreecommitdiff
path: root/docs/reference/PEC_sw_exposit_runoff.html
blob: b57c2f9fe8b351f3b5e76b6f8074160bfcf8d53d (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
<!-- Generated by pkgdown: do not edit by hand -->
<!DOCTYPE html>
<html>
  <head>
  <meta charset="utf-8">
<meta http-equiv="X-UA-Compatible" content="IE=edge">
<meta name="viewport" content="width=device-width, initial-scale=1.0">

<title>Calculate PEC surface water due to runoff and erosion as in Exposit 3 — PEC_sw_exposit_runoff • pfm</title>

<!-- jquery -->
<script src="https://code.jquery.com/jquery-3.1.0.min.js" integrity="sha384-nrOSfDHtoPMzJHjVTdCopGqIqeYETSXhZDFyniQ8ZHcVy08QesyHcnOUpMpqnmWq" crossorigin="anonymous"></script>
<!-- Bootstrap -->

<link href="https://maxcdn.bootstrapcdn.com/bootstrap/3.3.7/css/bootstrap.min.css" rel="stylesheet" integrity="sha384-BVYiiSIFeK1dGmJRAkycuHAHRg32OmUcww7on3RYdg4Va+PmSTsz/K68vbdEjh4u" crossorigin="anonymous">
<script src="https://maxcdn.bootstrapcdn.com/bootstrap/3.3.7/js/bootstrap.min.js" integrity="sha384-Tc5IQib027qvyjSMfHjOMaLkfuWVxZxUPnCJA7l2mCWNIpG9mGCD8wGNIcPD7Txa" crossorigin="anonymous"></script>

<!-- Font Awesome icons -->
<link href="https://maxcdn.bootstrapcdn.com/font-awesome/4.6.3/css/font-awesome.min.css" rel="stylesheet" integrity="sha384-T8Gy5hrqNKT+hzMclPo118YTQO6cYprQmhrYwIiQ/3axmI1hQomh7Ud2hPOy8SP1" crossorigin="anonymous">

<!-- clipboard.js -->
<script src="https://cdnjs.cloudflare.com/ajax/libs/clipboard.js/1.7.1/clipboard.min.js" integrity="sha384-cV+rhyOuRHc9Ub/91rihWcGmMmCXDeksTtCihMupQHSsi8GIIRDG0ThDc3HGQFJ3" crossorigin="anonymous"></script>

<!-- sticky kit -->
<script src="https://cdnjs.cloudflare.com/ajax/libs/sticky-kit/1.1.3/sticky-kit.min.js" integrity="sha256-c4Rlo1ZozqTPE2RLuvbusY3+SU1pQaJC0TjuhygMipw=" crossorigin="anonymous"></script>

<!-- pkgdown -->
<link href="../pkgdown.css" rel="stylesheet">
<script src="../pkgdown.js"></script>



<meta property="og:title" content="Calculate PEC surface water due to runoff and erosion as in Exposit 3 — PEC_sw_exposit_runoff" />

<meta property="og:description" content="This is a reimplementation of the calculation described in the Exposit 3.01 spreadsheet file,
in the worksheet &quot;Konzept Runoff&quot;. Calculation of sediment PEC values is not implemented." />
<meta name="twitter:card" content="summary" />



<!-- mathjax -->
<script src='https://mathjax.rstudio.com/latest/MathJax.js?config=TeX-AMS-MML_HTMLorMML'></script>

<!--[if lt IE 9]>
<script src="https://oss.maxcdn.com/html5shiv/3.7.3/html5shiv.min.js"></script>
<script src="https://oss.maxcdn.com/respond/1.4.2/respond.min.js"></script>
<![endif]-->


  </head>

  <body>
    <div class="container template-reference-topic">
      <header>
      <div class="navbar navbar-default navbar-fixed-top" role="navigation">
  <div class="container">
    <div class="navbar-header">
      <button type="button" class="navbar-toggle collapsed" data-toggle="collapse" data-target="#navbar">
        <span class="icon-bar"></span>
        <span class="icon-bar"></span>
        <span class="icon-bar"></span>
      </button>
      <span class="navbar-brand">
        <a class="navbar-link" href="../index.html">pfm</a>
        <span class="label label-default" data-toggle="tooltip" data-placement="bottom" title="Released package">0.5.2</span>
      </span>
    </div>

    <div id="navbar" class="navbar-collapse collapse">
      <ul class="nav navbar-nav">
        <li>
  <a href="../index.html">
    <span class="fa fa-home fa-lg"></span>
     
  </a>
</li>
<li>
  <a href="../reference/index.html">Reference</a>
</li>
      </ul>
      
      <ul class="nav navbar-nav navbar-right">
        <li>
  <a href="https://github.com/jranke/pfm">
    <span class="fa fa-github fa-lg"></span>
     
  </a>
</li>
      </ul>
      
    </div><!--/.nav-collapse -->
  </div><!--/.container -->
</div><!--/.navbar -->

      
      </header>

<div class="row">
  <div class="col-md-9 contents">
    <div class="page-header">
    <h1>Calculate PEC surface water due to runoff and erosion as in Exposit 3</h1>
    <small class="dont-index">Source: <a href='https://github.com/jranke/pfm/blob/master/R/PEC_sw_exposit_runoff.R'><code>R/PEC_sw_exposit_runoff.R</code></a></small>
    <div class="hidden name"><code>PEC_sw_exposit_runoff.Rd</code></div>
    </div>

    <div class="ref-description">
    
    <p>This is a reimplementation of the calculation described in the Exposit 3.01 spreadsheet file,
in the worksheet "Konzept Runoff". Calculation of sediment PEC values is not implemented.</p>
    
    </div>

    <pre class="usage"><span class='fu'>PEC_sw_exposit_runoff</span>(<span class='no'>rate</span>, <span class='no'>Koc</span>, <span class='kw'>DT50</span> <span class='kw'>=</span> <span class='fl'>Inf</span>, <span class='kw'>t_runoff</span> <span class='kw'>=</span> <span class='fl'>3</span>,
  <span class='kw'>exposit_reduction_version</span> <span class='kw'>=</span> <span class='fu'>c</span>(<span class='st'>"3.01"</span>, <span class='st'>"2.0"</span>), <span class='kw'>V_ditch</span> <span class='kw'>=</span> <span class='fl'>30</span>,
  <span class='kw'>V_event</span> <span class='kw'>=</span> <span class='fl'>100</span>)</pre>
    
    <h2 class="hasAnchor" id="arguments"><a class="anchor" href="#arguments"></a>Arguments</h2>
    <table class="ref-arguments">
    <colgroup><col class="name" /><col class="desc" /></colgroup>
    <tr>
      <th>rate</th>
      <td><p>The application rate in g/ha</p></td>
    </tr>
    <tr>
      <th>Koc</th>
      <td><p>The sorption coefficient to soil organic carbon</p></td>
    </tr>
    <tr>
      <th>DT50</th>
      <td><p>The soil half-life in days</p></td>
    </tr>
    <tr>
      <th>t_runoff</th>
      <td><p>The time between application and the runoff event, where degradation occurs, in days</p></td>
    </tr>
    <tr>
      <th>exposit_reduction_version</th>
      <td><p>The version of the reduction factors to be used</p></td>
    </tr>
    <tr>
      <th>V_ditch</th>
      <td><p>The volume of the ditch is assumed to be 1 m * 100 m * 30 cm = 30 m3</p></td>
    </tr>
    <tr>
      <th>V_event</th>
      <td><p>The unreduced runoff volume, equivalent to 10 mm precipitation on 1 ha</p></td>
    </tr>
    </table>
    
    <h2 class="hasAnchor" id="source"><a class="anchor" href="#source"></a>Source</h2>

    <p>Excel 3.01 spreadsheet available from
  <a href='https://www.bvl.bund.de/DE/04_Pflanzenschutzmittel/03_Antragsteller/04_Zulassungsverfahren/07_Naturhaushalt/psm_naturhaush_node.html#doc1400590bodyText3'>https://www.bvl.bund.de/DE/04_Pflanzenschutzmittel/03_Antragsteller/04_Zulassungsverfahren/07_Naturhaushalt/psm_naturhaush_node.html#doc1400590bodyText3</a></p>
    
    <h2 class="hasAnchor" id="value"><a class="anchor" href="#value"></a>Value</h2>

    <p>A list containing the following components</p><dl class='dl-horizontal'>
    <dt>perc_runoff</dt><dd><p>The runoff percentages for dissolved and bound substance</p></dd>
    <dt>runoff</dt><dd><p>A matrix containing dissolved and bound input for the different distances</p></dd>
    <dt>PEC_sw_runoff</dt><dd><p>A matrix containing PEC values for dissolved and bound substance
      for the different distances. If the rate was given in g/ha, the PECsw are in microg/L.</p></dd>
  </dl>

    
    <h2 class="hasAnchor" id="see-also"><a class="anchor" href="#see-also"></a>See also</h2>

    <div class='dont-index'><p><code><a href='perc_runoff_exposit.html'>perc_runoff_exposit</a></code> for runoff loss percentages and <code><a href='perc_runoff_reduction_exposit.html'>perc_runoff_reduction_exposit</a></code> for runoff reduction percentages used</p></div>
    

    <h2 class="hasAnchor" id="examples"><a class="anchor" href="#examples"></a>Examples</h2>
    <pre class="examples"><div class='input'>  <span class='fu'>PEC_sw_exposit_runoff</span>(<span class='fl'>500</span>, <span class='fl'>150</span>)</div><div class='output co'>#&gt; $perc_runoff
#&gt; dissolved     bound 
#&gt;     0.248     0.001 
#&gt; 
#&gt; $runoff
#&gt;           dissolved   bound   total
#&gt; No buffer     1.240 0.00500 1.24500
#&gt; 5 m           0.744 0.00300 0.74700
#&gt; 10 m          0.496 0.00075 0.49675
#&gt; 20 m          0.248 0.00025 0.24825
#&gt; 
#&gt; $PEC_sw_runoff
#&gt;           dissolved       bound    total
#&gt; No buffer  4.769231 0.019230769 4.788462
#&gt; 5 m        4.133333 0.016666667 4.150000
#&gt; 10 m       3.542857 0.005357143 3.548214
#&gt; 20 m       2.480000 0.002500000 2.482500
#&gt; </div></pre>
  </div>
  <div class="col-md-3 hidden-xs hidden-sm" id="sidebar">
    <h2>Contents</h2>
    <ul class="nav nav-pills nav-stacked">
      <li><a href="#arguments">Arguments</a></li>
      
      <li><a href="#source">Source</a></li>

      <li><a href="#value">Value</a></li>

      <li><a href="#see-also">See also</a></li>
      
      <li><a href="#examples">Examples</a></li>
    </ul>

  </div>
</div>

      <footer>
      <div class="copyright">
  <p>Developed by Johannes Ranke.</p>
</div>

<div class="pkgdown">
  <p>Site built with <a href="http://pkgdown.r-lib.org/">pkgdown</a>.</p>
</div>

      </footer>
   </div>

  

  </body>
</html>

Contact - Imprint